29 research outputs found

    Seismic evaluation method for existing reinforced concrete buildings in North of Morocco

    Get PDF
    The final publication is available at Springer via http://dx.doi.org/10.1007/s10518-019-00643-yThe purpose of this study is to seismically evaluate reinforced concrete buildings in the northern region of Morocco. In the past, the area have suffered from numerous earthquakes, lately the 2004 earthquake near the city of Al Hoceima (Mw of 6.4 causing more than 600 fatalities) and the region is constantly subject to seismic threats. A total number of 2746 residential buildings from the cities of Al Hoceima and Imzouren have been investigated for the purposes of this study. The proposed method adapts the Japanese Seismic Index Method making it more time-efficient and tuned to the context of the Moroccan construction. The method is based on a visual inspection of buildings and an in-depth insight of how constructions are designed and built in the region. The results show that Imzouren is more exposed to damage than the city of Al Hoceima is, mainly due to the soil nature. The method also shows that as the building’s height increases, it becomes more vulnerable. Furthermore, constructions that comply with the seismic regulations have a significant capacity to withstand damage without collapsing unlike other non-engineered buildings that have an almost non-existent ductility and can collapse soon during intense earthquakes.Peer ReviewedPostprint (author's final draft

    A Quantitative Assessment of Forest Cover Change in the Moulouya River Watershed (Morocco) by the Integration of a Subpixel-Based and Object-Based Analysis of Landsat Data

    Get PDF
    A quantitative assessment of forest cover change in the Moulouya River watershed (Morocco) was carried out by means of an innovative approach from atmospherically corrected reflectance Landsat images corresponding to 1984 (Landsat 5 Thematic Mapper) and 2013 (Landsat 8 Operational Land Imager). An object-based image analysis (OBIA) was undertaken to classify segmented objects as forested or non-forested within the 2013 Landsat orthomosaic. A Random Forest classifier was applied to a set of training data based on a features vector composed of different types of object features such as vegetation indices, mean spectral values and pixel-based fractional cover derived from probabilistic spectral mixture analysis). The very high spatial resolution image data of Google Earth 2013 were employed to train/validate the Random Forest classifier, ranking the NDVI vegetation index and the corresponding pixel-based percentages of photosynthetic vegetation and bare soil as the most statistically significant object features to extract forested and non-forested areas. Regarding classification accuracy, an overall accuracy of 92.34% was achieved. The previously developed classification scheme was applied to the 1984 Landsat data to extract the forest cover change between 1984 and 2013, showing a slight net increase of 5.3% (ca. 8800 ha) in forested areas for the whole region

    Numerical study of the smoke plume of the Jerada thermal power plant Morocco

    Get PDF
    Abstract The main goal of this study is firstly to model the phenomenon of advection and diffusion of the gaseous residues of coal combustion. On the other hand, to study the dispersion of this pollution by varying the parameters like the wind and the resources of pollution, where there are four emissions: SO2, CO, NO2 and PM10. The present model will compare estimating concentrations with the results found by the contribution of the thermal power plant of Jerada city, where the American Environmental Regulatory Model is used. The results suggest that SO2, PM10, NO2 and CO concentration simulated by turbulent k-Δ model in combination with the transport model of diluted species, at the 3h and 24h intervals, greater than their respective observed concentrations compared with the American Environmental Regulatory Model. The concentrations of the model found are very high and exceed the limit values under the study conditions. Indeed, the simulated model was used in 2D with a very low wind speed (10−4 m/s) and in the absence of gravity, hence the total neglect of altitude because the two sources of pollution are at the height of 120 m

    Influence of gravel and adjuvant on the compressive strength and water absorption of concrete

    Get PDF
    Concrete is the most commonly used material in civil engineering, given its economic cost and ease of manufacture. Its strength depends on the characteristics of its constituents. A good mix makes it possible to build solid, durable and economical structures. The present work aims to characterize the gravel of the Eastern region (quarry of eastern Morocco) by granulometric analysis and water absorption. Then, the studied gravel is used to produce three types of concrete (B20, B25 and B30), which were assessed in terms of water absorption and compressive strength. The last step is to study the effect of an adjuvant, more specifically a water reducer, on mechanical characteristics of local concrete. B25 concrete was chosen for the last step since it is the most used type in the region. Results show that adding a water reducer adjuvant, in this case ‘Chrysoplast’, can improve the compressive strength of concrete if the percentage added is accurately determined

    Seismic analysis of the zaouiat ait mellal twin tunnels of Agadir motorway (Morocco)

    Get PDF
    Proceeding of: Seventh International Congress 'Water, Waste and Environment" (EDE7-2019), Salé, Morocco, November 20-22, 2019Underground structures, such as tunnels, are vital for ensuring all kinds of transportation; and being buried under the surface makes them exposed to soil dynamics. Added to the moderate seismic activity in Morocco, the stability of tunnels is put to the test. This paper examines the interaction between the ZAM (Zaouit Ait Mellal ) twin tunnels between the cities of Marrakesh and Agadir, using the Difference Element Method provided by FLAC 2D software. The acceleration is introduced as the one related to the historic event of El centro 1940 with free-field boundary conditions in the numerical model, with three configurations: tunnel 1 without tunnel 2, tunnel 2 without tunnel 1 and tunnel 1 with tunnel 2. The results of the simulations indicate that the differences values of the maximum displacement, axial force and bending moment on structural elements are very noteworthy from the configuration of the tunnel (single) to the twin tunnels in order to prove the interaction between these latter under seismic loading

    Impact of the COVID-19 Pandemic on the Energy Use at the University of Almeria (Spain)

    Get PDF
    The COVID-19 pandemic has caused chaos in many sectors and industries. In the energy sector, the demand has fallen drastically during the first quarter of 2020. The University of Almeria campus also declined the energy consumption in 2020, and through this study, we aimed to measure the impact of closing the campus on the energy use of its different facilities. We built our analysis based upon the dataset collected during the year 2020 and previous years; the patterns evolution through time allowed us to better understand the energy performance of each facility during this exceptional year. We rearranged the university buildings into categories, and all the categories reduced their electricity consumption share in comparison with the previous year of 2019. Furthermore, the portfolio of categories presented a wide range of ratios that varied from 56% to 98%, the library category was found to be the most influenced, and the research category was found to be the least influenced. This opened questions like why some facilities were influenced more than others? What can we do to reduce the energy use even more when the facilities are closed? The university buildings presented diverse structures that revealed differences in energy performance, which explained why the impact of such an event (COVID-19 pandemic) is not necessarily relevant to have equivalent variations. Nevertheless, some management deficiencies were detected, and some energy savings measures were proposed to achieve a minimum waste of energy

    Numerical analysis of twin tunnels lining under different seismic conditions

    Get PDF
    The last seismic events showed that tunnel lining may suffer extensive damage. Employing numerical modeling has a great importance in predicting the seismic performance of tunnels. This paper tests the tunnel lining of the Zaouit Ait Mellal (ZAM) twin tunnels located between the cities of Marrakesh and Agadir in Morocco. Dynamic analysis was adopted by FLAC 2D software using the finite-difference elements. Four soil cross-sections were chosen, with different support devices installed along the twin tunnels, such as rock bolts and steel ribs. The seismic signals introduced as input were obtained from three different earthquakes: Al Hoceima 2004 in Morocco, EL Centro 1940 in the USA, and Kobe 1995 in Japan. The numerical results show that the deformation of the tunnel lining is more noteworthy in the sections using steel ribs compared to those using rock bolts, which is observed by the large values of relative displacement, reaching 1020 (mm) and 2.29 × 105 (N.m/m) of maximum bending moment. The analysis indicates that these sections present higher vulnerability during an earthquake, which should be considered when looking at the overall safety of the tunnel

    Evaluation of the Consistency of Simultaneously Acquired Sentinel-2 and Landsat 8 Imagery on Plastic Covered Greenhouses

    Get PDF
    Remote sensing techniques based on medium resolution satellite imagery are being widely applied for mapping plastic covered greenhouses (PCG). This article aims at testing the spectral consistency of surface reflectance values of Sentinel-2 MSI (S2 L2A) and Landsat 8 OLI (L8 L2 and the pansharpened and atmospherically corrected product from L1T product; L8 PANSH) data in PCG areas located in Spain, Morocco, Italy and Turkey. The six corresponding bands of S2 and L8, together with the normalized difference vegetation index (NDVI), were generated through an OBIA approach for each PCG study site. The coefficient of determination (r2) and the root mean square error (RMSE) were computed in sixteen cloud-free simultaneously acquired image pairs from the four study sites to evaluate the coherence between the two sensors. It was found that the S2 and L8 correlation (r2 > 0.840, RMSE < 9.917%) was quite good in most bands and NDVI. However, the correlation of the two sensors fluctuated between study sites, showing occasional sun glint effects on PCG roofs related to the sensor orbit and sun position. Moreover, higher surface reflectance discrepancies between L8 L2 and L8 PANSH data, mainly in the visible bands, were always observed in areas with high-level aerosol values derived from the aerosol quality band included in the L8 L2 product (SR aerosol). In this way, the consistency between L8 PANSH and S2 L2A was improved mainly in high-level aerosol areas according to the SR aerosol band

    Seismic risk in the city of Al Hoceima (north of Morocco) using the vulnerability index method, applied in Risk-UE project

    Get PDF
    The final publication is available at Springer via http://dx.doi.org/10.1007/s11069-016-2566-8Al Hoceima is one of the most seismic active regions in north of Morocco. It is demonstrated by the large seismic episodes reported in seismic catalogs and research studies. However, seismic risk is relatively high due to vulnerable buildings that are either old or don’t respect seismic standards. Our aim is to present a study about seismic risk and seismic scenarios for the city of Al Hoceima. The seismic vulnerability of the existing residential buildings was evaluated using the vulnerability index method (Risk-UE). It was chosen to be adapted and applied to the Moroccan constructions for its practicality and simple methodology. A visual inspection of 1102 buildings was carried out to assess the vulnerability factors. As for seismic hazard, it was evaluated in terms of macroseismic intensity for two scenarios (a deterministic and probabilistic scenario). The maps of seismic risk are represented by direct damage on buildings, damage to population and economic cost. According to the results, the main vulnerability index of the city is equal to 0.49 and the seismic risk is estimated as Slight (main damage grade equal to 0.9 for the deterministic scenario and 0.7 for the probabilistic scenario). However, Moderate to heavy damage is expected in areas located in the newer extensions, in both the east and west of the city. Important economic losses and damage to the population are expected in these areas as well. The maps elaborated can be a potential guide to the decision making in the field of seismic risk prevention and mitigation strategies in Al Hoceima.Peer ReviewedPostprint (author's final draft
    corecore